BACKUP ALARM REPLACEMENT
BRAKE AIR DRYER REPLACEMENT

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  903    904    905    906    907  908  909    910    911    912    913  
img
.
TM 5-3805-296-23-5
0353
REMOVAL
000353
NOTE
Tag and mark wiring harness connectors to aid in installation.
1. Disconnect backup alarm connector (Figure 1, Item 4) from chassis wiring harness connector
(Figure 1, Item 5).
2. Remove two bolts (Figure 1, Item 1), washers (Figure 1, Item 2), one clip (Figure 1, Item 3) and backup alarm
from (Figure 1, Item 6) machine.
Figure 1. Backup Alarm.
0353
END OF TASK
CLEANING AND INSPECTION
000353
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK
INSTALLATION
000353
1. Install backup alarm (Figure 1, Item 6), one clip (Figure 1, Item 3), two washers (Figure 1, Item 2), and
bolts (Figure 1, Item 1) on machine.
2. Connect backup alarm connector (Figure 1, Item 4) on chassis wiring harness connector (Figure 1, Item 5).
END OF TASK
END OF WORK PACKAGE