REMOVAL CONTINUED
1. Remove tiedown strap (Figure 1, Item 1) from ejector kickout switch (Figure 1, Item 4) and ejector
kickout switch wiring harness (Figure 1, Item 2). Discard tiedown strap.
2. Disconnect machine wiring harness connector (Figure 1, Item 7) from ejector kickout switch wiring harness
connector (Figure 1, Item 3).
3. Remove ejector kickout switch wiring harness connector (Figure 1, Item 3) from bracket (Figure 1, Item 6).
4. Remove ejector kickout switch (Figure 1, Item 4) and O-ring (Figure 1, Item 5) from fitting (Figure 1, Item 8).
Discard O-ring.