TM 5-3805-296-23-5
0340
ASSEMBLY
000340
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
Install tiedown straps as noted during removal.
1. Apply sealant to fitting (Figure 3, Item 1), install fitting on rear quick-release holding valve
(Figure 3, Item 8).
2. Apply sealant to fitting (Figure 3, Item 9), install fitting on rear quick-release holding valve (Figure 3, Item 8).
3. Apply sealant to T-fitting (Figure 3, Item 7), install T-fitting on rear quick-release holding valve
(Figure 3, Item 8).
4. Apply sealant to fitting (Figure 3, Item 6), install fitting on T-fitting (Figure 3, Item 7).
5. Apply sealant to fitting (Figure 3, Item 5), install fitting on T-fitting (Figure 3, Item 7).
6. Apply sealant to sensor (Figure 3, Item 4), install sensor (Figure 3, Item 5).
7. Install new tiedown strap (Figure 3, Item 3) on sensor wiring harness (Figure 3, Item 2) and sensor
(Figure 3, Item 4).
END OF TASK
0340-5