Figure 8. Battery Positive Cable and Batteries.
Figure 10. Battery Negative Cable.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  186    187    188    189    190  191  192    193    194    195    196  
img
.
TM 5-3805-296-23-5
0306
INSTALLATION CONTINUED
000306
NOTE
Install cables as noted during removal.
12. Connect cable (Figure 9, Item 3) to battery (Figure 9, Item 1) and battery (Figure 9, Item 5).
13. Connect cable (Figure 9, Item 10) to battery (Figure 9, Item 11) and battery (Figure 9, Item 6).
14. TIghten nut (Figure 9, Item 9) on terminal (Figure 9, Item 8) and position cover (Figure 9, Item 7) on terminal.
15. Repeat step 14 for three terminals underneath covers (Figure 9, Items 12, 4, and 2).
Figure 9. Crossover Battery Cables.
0306
0306-10