Figure 3. Brackets and Retaining Hardware.
Figure 5. Crossover Battery Cables.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  180    181    182    183    184  185  186    187    188    189    190  
img
.
TM 5-3805-296-23-5
0306
REMOVAL CONTINUED
NOTE
Tag and mark cable to aid in installation.
8. Lift cover (Figure 4, Item 4) and loosen nut (Figure 4, Item 7) on terminal (Figure 4, Item 6).
9. Repeat step 8 for terminal underneath cover (Figure 4, Item 2).
10. Disconnect cable (Figure 4, Item 3) from battery (Figure 4, Item 5) and battery (Figure 4, Item 1). Position cable
aside.
Figure 4. Battery Negative Cable.