TM 5-3805-296-23-4
0280
CONTROL VALVE PILOT HOSES INSTALLATION CONTINUED
CAUTION
Remove plugs and caps from hydraulic hoses and fittings. Failure to follow this caution
may result in damage to equipment.
NOTE
Install hydraulic hoses as tagged and marked during removal.
46. Install three O-rings (Figure 40, Items 13, 14, and 15) on lower fittings (Figure 40, Items 1, 2, and 4).
47. Install three lower fittings (Figure 40, Items 1, 2, and 4) on bracket (Figure 40, Item 3).
48. Install three new lockwashers (Figure 40, Item 8) and jamnuts (Figure 40, Item 9) on lower fittings
(Figure 40, Items 1, 2, and 4).
49. Install three hoses (Figure 40, Items 10, 11, and 12) on lower fittings (Figure 40, Items 1, 2, and 4) and tighten
tube nuts (Figure 40, Items 5, 6, and 7).
0280-52