TM 5-3805-296-23-4
0280
CONTROL VALVE PILOT HOSES INSTALLATION CONTINUED
CAUTION
Remove plugs and caps from hydraulic lines and fittings. Failure to follow this caution may
result in damage to equipment.
NOTE
Install hydraulic lines as tagged and marked during removal.
50. Install three O-rings (Figure 41, Items 10, 11, and 12) on lower fittings (Figure 41, Items 5, 7, and 8).
51. Install three lines (Figure 41, Items 1, 2, and 3) on lower fittings (Figure 41, Items 5, 7, and 8) and tighten tube
nuts (Figure 41, Items 4, 6, and 9).
Figure 41. Hydraulic Line Fittings.
0280