TM 5-3805-296-23-4
0280
CONTROL VALVE PILOT HOSES INSTALLATION CONTINUED
CAUTION
Remove plugs and caps from hydraulic hoses and fittings. Failure to follow this caution
may result in damage to equipment.
NOTE
Install hydraulic hoses as tagged and marked during removal.
32. Install three hoses (Figure 37, Items 11, 13 and 15) on fittings (Figure 37, Items 2, 14, and 9), and tighten tube
nuts (Figure 37, Items 1, 10, and 12).
33. Install three hoses (Figure 37, Items 4, 5, and 7) on fittings (Figure 37, Items 2, 14, and 9), and tighten tube
nuts (Figure 8, Items 3, 6, and 8).
Figure 37. Middle Draft Frame Hydraulic Fittings.