Table 1. Left Front Turn Signal Does Not Operate Continued.
Figure 3. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  1037    1038    1039    1040    1041  1042  1043    1044    1045    1046    1047  
img
.
TM 5-3805-296-23-2
0144
Table 1. Left Front Turn Signal Does Not Operate Continued.
0144
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Left Front Turn Signal Does
3. Using digital multimeter
Continuity Replace main cab wiring
Not Operate Continued
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C1
Proceed to Test Step 13.
terminal 60 (WP 0012, Figure 99)
No Continuity Proceed to step 4.
and all other terminals
in connector W-C1
(WP 0012, Figure 99).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C7
Proceed to Test Step 13.
terminal 30 (WP 0012, Figure 252)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C7
(WP 0012, Figure 252).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C7
Proceed to Test Step 13.
terminal 30 (WP 0012, Figure 252)
No Continuity Proceed to Test
and ground.
Step 11.
Test Step 11. Test for Shorted Dash
Wiring Harness.
1. Disconnect connector P-C2
(WP 0012, Figure 265) f
rom connector N-C1
(WP 0012, Figure 264).
2. Remove six bolts
(Figure 2, Item 1), washers
(Figure 2, Item 2), and instrument
panel cover (Figure 2, Item 3) from
ROPS (Figure 2, Item 4).
Figure 2. Instrument Panel Cover and Retaining Hardware.