TM 5-3805-296-23-2
0112
Table 1. Service Brakes Do Not Engage Correctly Continued.
0112
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Turn battery disconnect switch to
Service Brakes Do Not
ON position and start engine
Engage Correctly
(TM 5-3805-296-10). Idle engine
Continued
for 20 minutes or until air pressure
gauge reads normal operating
pressure (TM 5-3805-296-10).
8. Monitor and record air pressure
Air Pressure Within Specification
reading on gauge (Figure 1,
Turn ignition switch and battery
disconnect switch to OFF position
Item 3). Air Pressure should be
(TM 5-3805-296-10).
125 5 psi (862 34 kPa).
Close valve (Figure 2, Item 1).
Disconnect quick disconnect hose
(Figure 1, Item 5) from quick disconnect
coupling half (Figure 1, Item 1).
Remove quick disconnect coupling half
(Figure 1, Item 1) from air drain
connection (Figure 1, Item 2).
Proceed to Test Step 12.
Air Pressure Not Within
Specification Turn ignition switch
and battery disconnect switch to OFF
position (TM 5-3805-296-10).
Close valve (Figure 2, Item 1).
Disconnect quick disconnect hose
(Figure 1, Item 5) from quick disconnect
coupling half (Figure 1, Item 1).
Remove quick disconnect coupling half
(Figure 1, Item 1) from air drain
connection (Figure 1, Item 2).
(WP 0261).
Proceed to Test Step 9.
0112-6