Table 1. 1775 Implement Pump Pressure Calibration Switch Diagnostic Codes Continued.
Table 1. 1775 Implement Pump Pressure Calibration Switch Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  369    370    371    372    373  374  375    376    377    378    379  
img
.
TM 5-3805-296-23-2
0090
Table 1. 1775 Implement Pump Pressure Calibration Switch Diagnostic Codes Continued.
090
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
4. Select status group #12 (Figure 1,
1775-04 Implement Pump
All Values Change Accordingly
Item 1) and view Implement Pump
Pressure Calibration Switch
Replace calibration pressure switch
Pressure Value (Figure 1, Item 2)
Voltage Below Normal
(WP 0173).
while performing the following:
Continued
Proceed to Test Step 5.
a. Connect jumper wire between
One or More Values Do Not Change
connector A-C12 terminal A
Accordingly Proceed to Test Step 2.
and terminal B (WP 0012,
Figure 103). Valve displays
High (Figure 1, Item 2).
b. Connect jumper wire between
connector A-C12 terminal A
and terminal C (WP 0012,
Figure 103). Valve displays
Low (Figure 1, Item 2).
c.
Connect jumper wire between
connector A-C12 terminal B
and terminal C (WP 0012,
Figure 103). Valve displays
Disabled or Not Installed
(Figure 1, Item 2).
Figure 1. Implement Pump Pressure Status.
0090
0090-6