Table 1. 1775 Implement Pump Pressure Calibration Switch Diagnostic Codes Continued.
090
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
1775-03 Implement Pump
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C1
Voltage Above Normal
Proceed to Test Step 4.
terminal 43 (WP 0012, Figure 99)
Continued
No Continuity Proceed to step 5.
and all other terminals in
connector W-C1 (WP 0012,
Figure 99).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 4.
terminal 59 (WP 0012, Figure 88)
No Continuity Proceed to step 6.
and all other terminals in
connector W-C12 (WP 0012,
Figure 88).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 4.
terminal 59 (WP 0012, Figure 88)
No Continuity Proceed to step 7.
and all terminals in connector
W-C13 (WP 0012, Figure 89).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 4.
terminal 50 (WP 0012, Figure 88)
No Continuity Proceed to step 8.
and all other terminals in
connector W-C12 (WP 0012,
Figure 88).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 4.
terminal 50 (WP 0012, Figure 88)
No Continuity Replace transmission/
and all terminals in connector
chassis ECM (WP 0495).
W-C13 (WP 0012, Figure 89).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
1775-3 Implement Pump Pressure
Calibration Switch Voltage Above
originally sent you here. Perform
Normal Becomes Inactive
Troubleshooting complete.
1775-3 Implement Pump Pressure
Calibration Switch Voltage Above
Normal Remains Active Repeat
troubleshooting from the beginning.
0090-4