Table 1. 1430 Scraper System Air Pressure Diagnostic Codes Continued.
Figure 3. Splash Shield and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  318    319    320    321    322  323  324    325    326    327    328  
img
TM 5-3805-296-23-2
0085
Table 1. 1430 Scraper System Air Pressure Diagnostic Codes Continued.
085
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 13. Test Push Frame
1430-03 Scraper Air
Wiring Harness for High Resistance
Pressure Sensor Voltage
or Open.
Above Normal Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Connect jumper wire between
terminal A and terminal B of
connector AF-C4
(WP 0012, Figure 168).
3. Disconnect connector AF-C1
(WP 0012, Figure 164) from
connector AE-C2
(WP 0012, Figure 163).
4. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 14.
between connector AF-C1
Resistance Greater Than 5.0 Ohms
terminal 14 and terminal 18
Replace push frame wiring harness
(WP 0012, Figure 164).
(WP 0347).
Proceed to Test Step 17.
Test Step 14. Test Draft Frame and
Bowl Side Wiring Harness for High
Resistance or Open.
1. Remove jumper wire from terminal
A and terminal B of connector
AF-C4 (WP 0012, Figure 168).
2. Connect jumper wire between
terminal 14 and terminal 18 of
connector AE-C2
(WP 0012, Figure 163).
3. Disconnect connector AE-C1
(WP 0012, Figure 144) from
connector E-C2
(WP 0012, Figure 143).
4. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 15.
between connector AE-C1
Resistance Greater Than 5.0 Ohms
terminal 21 and terminal 25
Replace draft frame and bowl side
(WP 0012, Figure 144).
wiring harness (WP 0348).
Proceed to Test Step 17.