Table 1. 1430 Scraper System Air Pressure Diagnostic Codes Continued.
Figure 2. Splash Shield and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  315    316    317    318    319  320  321    322    323    324    325  
img
TM 5-3805-296-23-2
0085
Table 1. 1430 Scraper System Air Pressure Diagnostic Codes Continued.
085
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 9. Test Draft Frame and
1430-03 Scraper Air
Bowl Side Wiring Harness for High
Pressure Sensor Voltage
Resistance or Open.
Above Normal Continued
1. Remove jumper wire from terminal
C and terminal B of connector
AF-C4 (WP 0012, Figure 168).
2. Connect jumper wire between
terminal 14 and terminal 19 of
connector AE-C2
(WP 0012, Figure 163).
3. Disconnect connector AE-C1
(WP 0012, Figure 144) from
connector E-C2
(WP 0012, Figure 143).
4. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 10.
between connector AE-C1
Resistance Greater Than 5.0 Ohms
terminal 21 and terminal 26
Replace draft frame and bowl side
(WP 0012, Figure 144).
wiring harness (WP 0348).
Proceed to Test Step 17.
0085-7


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.