Table 1. 1294 Ejector Return Indicator Diagnostic Codes Continued.
APRON FLOAT INDICATOR DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  291    292    293    294    295  296  297    298    299    300    301  
img
TM 5-3805-296-23-2
0082
Table 1. 1294 Ejector Return Indicator Diagnostic Codes Continued.
082
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Using digital multimeter
1294-06 Ejector Return
Continuity Replace main cab wiring
(WP 0540), test for continuity
Lamp Current Above Normal
harness (WP 0505).
between connector W-C7
Continued
Proceed to Test Step 4.
terminal 26 (WP 0012, Figure 252)
No Continuity Proceed to step 4.
and all other terminals in
connector W-C7
(WP 0012, Figure 252).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 15 (WP 0012, Figure 89)
No Continuity Proceed to step 5.
and all other terminals in
connector W-C13
(WP 0012, Figure 89).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 15 (WP 0012, Figure 89)
No Continuity Proceed to step 6.
and all terminals in connector
W-C12 (WP 0012, Figure 88).
6. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 15 (WP 0012, Figure 89)
No Continuity Replace transmission/
and ground.
chassis ECM (WP 0495).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1294-6 Ejector Return Lamp Current
diagnostic codes (WP 0008).
Above Normal Becomes Inactive
Troubleshooting complete. Proceed to
step 4.
1294-6 Ejector Return Lamp Current
Above Normal Remains Active
Repeat troubleshooting from the
beginning.
4. If removed, install lower and upper
plenum on ROPS (WP 0504).
END OF WORK PACKAGE
0082-11/(12 blank)