TM 5-3805-296-23-2
0082
Table 1. 1294 Ejector Return Indicator Diagnostic Codes Continued.
082
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Dash
1294-03 Ejector Return
Wiring Harness.
Lamp Voltage Above Normal
1. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect connector P-C27 from
instrument panel. Remove ejector
return LED from connector P-C27
(WP 0506) (Figure 1).
Figure 1. Connector P-C26 and Connector P-C27 on Instrument Panel.
0082
3. Remove upper and lower plenum
from ROPS (WP 0504).
4. Disconnect connector P-C1
(WP 0012, Figure 253) from
connector W-C7
(WP 0012, Figure 252).
Continuity Replace dash wiring
harness (WP 0510).
between connector P-C1
Proceed to Test Step 3.
terminal 26 (WP 0012, Figure 253)
No Continuity Proceed to Test
and all other terminals in
Step 2.
connector P-C1
(WP 0012, Figure 253).