Table 1. 1280 Ejector Reverse Proportional Solenoid Diagnostic Codes Continued.
Table 1. 1280 Ejector Reverse Proportional Solenoid Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  176    177    178    179    180  181  182    183    184    185    186  
img
.
TM 5-3805-296-23-2
0075
Table 1. 1280 Ejector Reverse Proportional Solenoid Diagnostic Codes Continued.
075
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
1280-13 Ejector Reverse
Solenoid Out of Calibration
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Transmission/Chassis ECM Detects Ejector Reverse Solenoid Out of
Calibration.
POSSIBLE CAUSE
Ejector Reverse Solenoid Requires Calibration.
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Test Step 1. Test Calibration Tool.
Monitor Implement Pump Pressure
Status Remains Low Proceed to
Status (Figure 10, Item 1) while
Test Step 2.
performing bowl solenoid calibration
Status Changes From Low to High
(WP 0173).
Proceed to Test Step 5.
Figure 10. Implement Pump Pressure Status.