Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
Figure 10. Front Cover.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  83    84    85    86    87  88  89    90    91    92    93  
img
.
TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Bowl
1276-06 Bowl Down
Down Solenoid.
Solenoid Current Above
1. Turn ignition switch and battery
Normal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove two bolts
(Figure 9, Item 3), washers
(Figure 9, Item 2), and hydraulic
tube clamp (Figure 9, Item 4) from
hydraulic tube (Figure 9, Item 5)
and mounting boss
(Figure 9, Item 1).
Figure 9. Hydraulic Tube Clamp.