Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  79    80    81    82    83  84  85    86    87    88    89  
img
.
TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
4. Using digital multimeter
1276-05 Bowl Down
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Solenoid Current Below
Proceed to Test Step 4.
between connector AE-C1
Normal Continued
Resistance Greater Than 5.0 Ohms
terminal 5 and terminal 7
Replace draft frame and bowl side
(WP 0012, Figure 144).
wiring harness (WP 0348).
Proceed to Test Step 6.
Test Step 4. Test Hitch Wiring
Harness for High Resistance or
Open.
1. Remove jumper wire from
terminal 5 and terminal 7 of
connector AE-C5
(WP 0012, Figure 145).
2. Connect jumper wire between
terminal 5 and terminal 7
of connector E-C2
(WP 0012, Figure 143).
3. Lower left frame access plate
(WP 0376).
4. Remove four bolts
(Figure 8, Item 1), washers
(Figure 8, Item 2), bushings
(Figure 8, Item 3), and splash
shield (Figure 8, Item 4) from
machine.
Figure 8. Splash Shield and Retaining Hardware.