Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes.
Figure 2. Front Cover.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
img
.
TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted
1276-03 Bowl Down
Implement Wiring Harness.
Solenoid Voltage Above
1. Turn ignition switch and battery
Normal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove two bolts
(Figure 1, Item 3), washers
(Figure 1, Item 2), and hydraulic
tube clamp (Figure 1, Item 4) from
hydraulic tube (Figure 1, Item 5)
and mounting boss
(Figure 1, Item 1).
Figure 1. Hydraulic Tube Clamp.