Table 1. 1275 Bowl Up Proportional Solenoid Diagnostic Codes Continued.
BOWL DOWN PROPORTIONAL SOLENOID DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  65    66    67    68    69  70  71    72    73    74    75  
img
TM 5-3805-296-23-2
0070
Table 1. 1275 Bowl Up Proportional Solenoid Diagnostic Codes Continued.
070
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Perform Joystick Bowl
1275-13 Bowl Up Solenoid
Lever Sensor Calibration.
Out of Calibration
Continued
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick bowl lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
Calibration Value Too Low Replace
implement control joystick (WP 0503).
Calibrate joystick (WP 0173).
Calibration Value Too Large
Replace implement control joystick
(WP 0503).
Calibrate joystick (WP 0173).
END OF WORK PACKAGE
0070-19/(20 blank)