TM 5-3805-296-23-2
0070
Table 1. 1275 Bowl Up Proportional Solenoid Diagnostic Codes Continued.
070
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Perform Joystick Bowl
Lever Sensor Calibration.
Out of Calibration
Continued
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick bowl lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
implement control joystick (WP 0503).
Calibrate joystick (WP 0173).
Replace implement control joystick
(WP 0503).
Calibrate joystick (WP 0173).
END OF WORK PACKAGE
0070-19/(20 blank)