TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
1276-03 Bowl Down Solenoid Test Step 5. Verify Malfunction is
Resolved.
Voltage Above Normal
1. Ensure all harness connectors are
Continued
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1276-3 Bowl Down Solenoid Voltage
diagnostic codes (WP 0008).
Above Normal Becomes Inactive
Proceed to step 4.
1276-3 Bowl Down Solenoid Voltage
Above Normal Remains Active
Repeat troubleshooting from the
beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install splash shield
(Figure 5, Item 4), four bushings
(Figure 5, Item 3), washers
(Figure 5, Item 2), and bolts
(Figure 5, Item 1) on machine.
6. If lowered, install left frame access
plate (WP 0376).
7. Install rear cover
(Figure 3, Item 3), two washers
(Figure 3, Item 2), and bolts
(Figure 3, Item 1) on machine.
8. Install cover (Figure 2, Item 3), four
washers (Figure 2, Item 1), and
bolts (Figure 2, Item 2) on
machine.
9. Install hydraulic tube clamp
(Figure 1, Item 4), two washers
(Figure 1, Item 2), and bolts
(Figure 1, Item 3) on mounting
boss (Figure 4, Item 1) and
hydraulic tube (Figure 4, Item 5).
10. Troubleshooting complete.
0071-8