• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 0968 Transmission Hold Indicator Diagnostic Codes Continued.
BOWL UP PROPORTIONAL SOLENOID DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  46    47    48    49    50  51  52    53    54    55    56  
img
TM 5-3805-296-23-2
0069
Table 1. 0968 Transmission Hold Indicator Diagnostic Codes Continued.
069
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Using digital multimeter
0968-06 Gear Hold Lamp
Continuity Replace main cab wiring
(WP 0540), test for continuity
Current Above Normal
harness (WP 0505).
between connector W-C7
Continued
Proceed to Test Step 4.
terminal 23 (WP 0012, Figure 252)
No Continuity Proceed to step 4.
and all other terminals
in connector W-C7
(WP 0012, Figure 252).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 41 (WP 0012, Figure 89)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C13
(WP 0012, Figure 89).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 41 (WP 0012, Figure 89)
No Continuity Proceed to step 6.
and all terminals in connector
W-C12 (WP 0012, Figure 88).
6. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 41 (WP 0012, Figure 89)
No Continuity Replace transmission/
and ground.
chassis ECM (WP 0495).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
968-6 Gear Hold Lamp Current
diagnostic codes (WP 0008).
Above Normal Becomes Inactive
Proceed to step 4.
968-6 Gear Hold Lamp Current
Above Normal Remains Active
Repeat troubleshooting from the
beginning.
4. Install instrument panel and
plenum (WP 0506).
5. Troubleshooting complete.
END OF WORK PACKAGE
0069-11/(12 blank)


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.