• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
USER DEFINED SHUTDOWN EVENT CODE
Table 1. E265 User Defined Shutdown Event Code Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  723    724    725    726    727  728  729    730    731    732    733  
img
. . . .
TM 5-3805-296-23-1
0045
Table 1. E265 User Defined Shutdown Event Code.
0045
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
E265 User Defined
Shutdown
Perform this test only if condition is active.
EVENT CODE SET CONDITION
Tractor Ground Level Shutdown Switch Activated.
POSSIBLE CAUSE
Operator Set Tractor Ground Level Shutdown Switch To Stop Position.
Fault on Ground Level Shutdown Switch Circuits.
Test Step 1. Verify Tractor Ground
Level Shutdown Switch Position.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Verify position of tractor ground
Switch Set to Stop Position Set
level (emergency) shutdown
switch to Run position.
switch (TM 5-3805-296-10).
Proceed to Test Step 3.
Switch Set to Run Position
Proceed to Test Step 2.
Test Step 2. Check For Active
Diagnostic Codes.
1. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
2. At MSD, check for active
Diagnostic Code(s) Active
diagnostic code(s) (WP 0008).
Diagnose and repair active diagnostic
code(s) (WP 0005).
Proceed to Test Step 3.
No Active Diagnostic Code(s)
Perform diagnostic procedure 0267
Engine Shutdown Switch Diagnostic
Code (WP 0005).
Proceed to Test Step 3.
0045-2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.