Table 1. E172 High Air Filter Restriction Event Code.
Table 1. E194 High Exhaust Temperature Event Code.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  719    720    721    722    723  724  725    726    727    728    729  
img
. . .
4
TM 5-3805-296-23-1
0044
TROUBLESHOOTING PROCEDURES
-
E194 HIGH EXHAUST TEMPERATURE EVENT CODE
004
4
INITIAL SETUP
References
Tools and Special Tools
0
0
Adapter, Communication
WP 0005
0
(WP 0550, Item 3)
WP 0167
0
0
Software Kit (ET)
WP 0207
0
(WP 0550, Item 168)
WP 0230
0
0
Test Set, Electronic (MSD)
Equipment Conditions
(WP 0550, Item 175)
0
0
Machine parked (TM 5-3805-296-10)
0
Materials/Parts
0
MSD connected (WP 0008)
0
Rag, Wiping (WP 0549, Item 28)
0
GENERAL
00044
This work package contains field maintenance troubleshooting information for the Military 621G Scraper. Each
malfunction or symptom is followed by the possible cause(s) and suggested remedy or remedies. Use this work
package to help isolate and correct system problems. Ensure all PMCS and operator troubleshooting procedures
(TM 5-3805-296-10) have been performed.