TM 5-3805-296-23-1
0044
Table 1. E194 High Exhaust Temperature Event Code Continued.
044
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 4. Verify Malfunction is
E194 High Exhaust
Resolved.
Temperature - Derate
1. Turn battery disconnect switch to
Continued
ON position and start engine
(TM 5-3805-296-10).
2. At MSD, check for active
Diagnostic Code(s) Active
Diagnose and repair active diagnostic
Proceed to step 3.
No Active Diagnostic Code(s)
Proceed to step 3.
3. Verify correct operation of machine
(TM 5-3805-296-10).
4. At MSD, check for active event
Becomes Inactive Troubleshooting
complete.
Remains Active Repeat
troubleshooting from the beginning.
END OF WORK PACKAGE
0044-3/(4 blank)