TM 5-3805-296-23-1
0026
Table 1. 0174 Fuel Temperature Sensor Diagnostic Codes Continued.
026
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0174-04 Fuel Temperature
Test Step 5. Verify Malfunction is
Sensor Voltage Below
Resolved.
Normal Continued
1. Ensure all harness connectors are
connected.
2. At MSD, check for active
174-4 Fuel Temperature Sensor
Voltage Below Normal Becomes
Inactive Proceed to step 3.
174-4 Fuel Temperature Sensor
Voltage Below Normal Remains
Active Repeat troubleshooting from
the beginning.
3. If removed, install splash shield
(Figure 5, Item 4), four bushings
(Figure 5, Item 3), washers
(Figure 5, Item 2), and bolts
(Figure 5, Item 1) on machine.
Figure 5. Splash Shield and Retaining Hardware.
0026
4. If lowered, install left frame access
plate (WP 0376).
5. Troubleshooting complete.
END OF WORK PACKAGE