• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 0174 Fuel Temperature Sensor Diagnostic Codes Continued.
Table 1. 0174 Fuel Temperature Sensor Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  552    553    554    555    556  557  558    559    560    561    562  
img
. .
TM 5-3805-296-23-1
0026
Table 1. 0174 Fuel Temperature Sensor Diagnostic Codes Continued.
026
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 9. Verify Malfunction is
0174-03 Fuel Temperature
Resolved.
Sensor Voltage Above
1. Ensure all harness connectors are
Normal Continued
connected.
2. At MSD, check for active
174-3 Fuel Temperature Sensor
Voltage Above Normal Becomes
diagnostic codes (WP 0008).
Inactive Proceed to step 3.
174-3 Fuel Temperature Sensor
Voltage Above Normal Remains
Active Repeat troubleshooting from
the beginning.
3. If removed, install splash shield
(Figure 3, Item 4), four bushings
(Figure 3, Item 3), washers
(Figure 3, Item 2), and bolts
(Figure 3, Item 1) on machine.
Figure 3. Splash Shield and Retaining Hardware.
0026
4. If lowered, install left frame access
plate (WP 0376).
5. Troubleshooting complete.
0026-8