AIRFLOW VALVE - Continued
AIRFLOW VALVE - Continued

Technical Manual For Airflow Valve
Page Navigation
  13    14    15    16    17  18  19    20    21    22    23  
img
. . .
TM 3-4240-302-30&P-6
2-7. AIRFLOW VALVE (CONT).
LOCATION
ITEM
ACTION
REMOVAL
Airflow Valve
S1 sensitive switch and
1.
Tag and unsolder wire (1) from normally
adapter
closed (NC) terminal on switch (51).
2.
Tag and unsolder wire (2) from common (C)
terminal on switch (S1).
3.
Remove two nuts (3) and screws (4).
4.
Remove switch (S1) and adapter (5).
5.
Remove and retain capacitor (6) and diode (7)
(p. 2-15).
INSTALLATION
1.
Install S1 sensitive switch and adapter (5) using
two screws (4) and nuts (3).
2.
Solder wire (1) to normally closed (NC)
terminal of S1 sensitive switch.
3.
Reinstall diode (7) and capacitor (6) (p. 2-15).
4.
Coat electrical connections with oil varnish
(item 3, app C).
2-16


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.