• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AIRFLOW VALVE - Continued
AIRFLOW VALVE - Continued

Technical Manual For Airflow Valve
Page Navigation
  10    11    12    13    14  15  16    17    18    19    20  
img
. .
TM 3-4240-302-30&P-6
LOCATION
ITEM
ACTION
INSTALLATION
Airflow Valve
RFI filter FL1
1.
Using old RFI filter FL1 as a pattern, cut wires
on new RFI filter to length. Solder ground wire
to shielding of each filter wire. Tape
connection. Install terminal lugs on ground
wires.
2.
Mount RFI filter FL1 (9) in airflow valve (26)
using two screws (6) and nuts (7).
3.
Solder wires (8 and 10) to lugs on FL1 filter FL1
(9). Refer to wiring diagram (p. 2-19).
4.
Replace tape (1 through 5) (item 2, app C).
2-13


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.