TM 3-4240-302-30&P-6
LOCATION
ITEM
ACTION
INSTALLATION
Airflow Valve
Motor with RFI filter FL2
7.
Install screw (2), GRD 4 terminal lug (3), and
nut (1).
8.
Bring cabling between motor (20) and RFI filter
FL2 (8) together and install tiedown strap (9),
screw (11), and nut (10).
9.
REMOVAL
Airflow Valve
RFI filter FL1
1.
Cut and remove twine (1 thru 5) and separate
the wires.
2.
Remove two screws (6) and nuts (7).
3.
Tag and unsolder one pair of wires (8) from
RFI filter FL1 (9) negative (-) terminal.
4.
Tag and unsolder one pair of wires (10) from
RFI filter FL1 (9) positive (+) terminal.
2-11