TM 9-4940-568-34
5-9
a.
Removal.
(1)
Remove air filter cover and base (TM 9-4940-568-20).
8
2
6
1
4
7
3
5
NOTE
Tag and mark all hoses and connectors before removal.
Cap and plug hydraulic hoses and fittings after disconnecting.
Remove cable ties as required to remove wires and hydraulic hoses.
Place drain pan under hydraulic hoses as necessary.
Generator set can be removed with generator set housing installed or removed. Generator
set housing shown installed.
(2)
Position drain pan under hydraulic pump (1).
(3)
Remove hose (2) and preformed packing (3), hose (4) and preformed packing (5), hose (6) and
preformed packing (7) from hydraulic pump (1) and position hoses below generator set enclosure (8).