TM 9-4940-568-34
5-7
3
5
2
1
4
3
5
3
2
1
4
Storage rack weighs approximately 300 lbs (136 kg). Attach suitable lifting device to
prevent possible injury to personnel.
NOTE
If installing generator housing with generator set on flatrack, perform Steps (7) through
(11).
(7)
With the aid of an assistant, attach lifting device to storage rack (1).
(8)
With the aid of an assistant, remove two locknuts (2), washers (3) and screws (4), pivot storage rack (1)
down. Discard locknuts.
(9)
Install two screws (4), washers (3) and locknuts (2).
(10)
Install two bottom locknuts (5) on screws (4) and storage rack (1)
(11)
Remove lifting device from storage rack (1).
c.
Follow-On Maintenance:
Install generator set (if necessary), (Para 5-3).
Connect batteries, (TM 9-4940-568-10).
Start generator and check for proper operation, (TM 9-4940-568-10).
END OF TASK