TM 9-4940-568-34
3-105
3-31. FIVE FUNCTION CONTROL VALVE MOUNTING BRACKET REPLACEMENT
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL SETUP
Tools
Tool Kit, General Mechanics
(Item 67, Appendix F)
Materials/Parts
Lockwasher (4) (Item 44, Appendix E)
Lockwasher (4) (Item 45, Appendix E)
Materials/Parts Continued
Lockwasher (10) (Item 47, Appendix E)
Lockwasher (2) (Item 46, Appendix E)
Lockwasher (Item 43, Appendix E)
Equipment Condition
FRS unloaded, (TM 9-4940-568-10).
Batteries disconnected (TM 9-4940-568-10).
a.
Removal
CAUTION
When
replacing
brackets,
replace one bracket at a time.
Failure to comply may result in
damage to equipment.
(1) Remove two nuts (1), lockwashers (2),
spacer plate (3), anchor bracket (4) and
screws (5) from cover (6). Discard
lockwashers.
(2) Remove screw (7), lockwasher (8) and
rubber latch (9) from left side bracket
(10). Discard lockwasher.
(3) Repeat Steps (1) and (2) for other side
of control valve.
(4) Remove four screws (11), lockwashers
(12), washers (13), and cover (6).
Discard lockwashers.
(5) Remove nut (14), washer (15), and
remote control power cable (16) from
left side bracket (10). Discard
lockwasher.
(6) Remove nut (17), lockwasher (18), and
crane main power switch (19) from left
side bracket (10).
18
17
15
14
19
16
10
12
9
3
11
13
6
10
7
8
1
2
5
4