TM 9-4940-568-20
11-25
b. Installation.
1
2
5
6
3
4
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from
open fire and use in well-ventilated area. If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately with soap and water.
(1)
Apply sealing compound to threads of gage (5), nipple (4) and hose (1).
(2)
Install elbow (3) on air compressor gage (5).
(3)
Install air compressor gage (5), elbow (3), nipple (4) and union (2) to air compressor platform (6)
(4)
Install hose (1) on union (2).
c.
Follow-On Maintenance:
Start generator, (TM 9-4940-568-10).
Start compressor and check operation of gage, (TM 9-4940-568-10).
END OF TASK