TM 9-4940-568-20
11-21
NOTE
Install wires as noted prior to
removal.
(4)
Route wiring harness (6) through junction
box (3) and tighten nut (5). Connect wires
(4).
(5)
Install access plate (2) with two screws (1)
on junction box (3).
c.
Follow-On Maintenance:
Fill air compressor crankcase with oil, (Para 11-9).
Connect batteries, (TM 9-4940-568-10).
Start generator, (TM 9-4940-568-10).
Start air compressor and check operation, (TM 9-4940-568-10).
END OF TASK
6
3
5
2
1
3
4