TM 9-4940-568-20
5-41
5-10. OVERLOAD SHUTDOWN CABLE REPLACEMENT
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL SETUP
Tools
Tool Kit, General Mechanics
(Item 30, Appendix G)
Equipment
Condition
FRS unloaded (TM 9-4940-568-10)
Equipment
Condition (Cont)
Batteries disconnected
(TM 9-4940-568-10)
Overload shutdown cable
removed from junction
box (para 5-4).
General Safety Instructions
To prevent personal injury, make sure batteries
are disconnected before working on electrical
components.
a. Removal
NOTE
Cut cable ties as required.
Remove cushion clamps as
required.
Tag and mark all wires prior to
removal.
(1) Disconnect overload shutdown cable (1)
from overload shutdown box (2).
NOTE
Note routing of cable
before removing.
(2) Remove overload shutdown cable (1)
from crane (3).
3