TM 9-4940-568-20
5-38
5-8.
POWER CABLE REPLACEMENT (Continued)
b. Installation
(1) Position retaining nut (9) and rubber
grommet (10) on harness (10) and
install on junction box (5).
(2) Connect black wire (6) and install screw
(7) and ground wire (8) in junction box
(5).
(3) Install cover (4) and two screws (3) on
junction box (5).
(4) Connect power cable connector (1) to
hydraulic manifold connector (2).
END OF TASK
Follow-On Maintenance
Connect batteries
(TM 9-4940-568-10)
Deploy outrigger to
verify fault is corrected
(TM 9-4940-568-10)