TM 9-4940-568-10
2-146
2-30. SHELTER HEATER OPERATION.
2
3
4
1
NOTE
24 VOLT DC PANEL power switch must be in the ON position.
(1)
Install shelter canvas (1) on shelter
(2)
Start generator (Para 2-15).
(3)
To start shelter heater (2), depress the switch (3) to the left ( ) position and the red and green lights will
illuminate.
(4)
Adjust temperature setting by adjusting the temperature control dial (4).
(5)
To shutdown shelter heater (2), depress switch to the right ( ) position and the red and green lights will go out.
Prior to turning off MASTER DISCONNECT switch, allow shelter heater to perform
cool down cycle (approx. 3 minutes) until fan stops. Failure to comply may result in a
fire causing injury or death to personnel.
(6)
Allow the heater fan to stop before shutting down.
(7)
Shutdown generator.