37
13
50
20
19
12
10
11
14
14
TM 9-4940-568-10
2-145
Keep all personnel clear of system when retracting O/R beams and jacks. The beams can
crush hands, and retracting the jacks drops the flatrack back on the ground which could
cause injury to personnel.
Ensure that no tools, parts, personnel or objects are on outriggers before retracting, to
prevent personnel injury.
(6)
Move O/R EXT lever (13) to IN position until outrigger beams (14) are fully retracted.
NOTE
Ensure chain of pin is looped over top of outrigger latch.
(7)
Remove pin (10) and retaining pin (11)and place left outrigger latch (12) in closed position. Install
retaining pin and pin.
(8)
Repeat Step (7) for right outrigger latch.
(9)
Position MAIN POWER switch (37) to OFF.
(10)
Close outrigger control cover (50).
(11)
Stow crane boom light (Para 2-28).
NOTE
Ensure dust cap is installed on remote control hookup.