TM 9-4940-568-10
2-110
2-22. EXOTHERMIC CUTTING SYSTEM OPERATION (CONT).
13
11
9
15
(9)
Loosen collet nut (13) 1/2 turn and remove recessed rod (15), if necessary.
(10)
Remove collet nut (13) from torch head (9).
(11)
Remove leather shield (11) from torch head (9).
(12)
Install collet nut (13) onto torch head (9) and tighten collet nut.
12
11
10
9
(13)
Stow striker plate (10), torch head (9), and leather shield (11) in welding cabinet (12).