TM 5-4930-244-14
(10)
Remove wire #41 (16) from "run" terminal of start-off-run switch (12).
(11)
Remove wire #33 (17) from wire #32 (18) of start-off-run switch (22).
(12)
Remove wire #34 (19) from wire #32 (18) and "run" terminal of start-off-run switch (12).
(13)
Remove jumper wire #32 (18) from "run" and "start" terminals of start-off-run switch (12).
(14)
Remove wire #35 (20) from "run" terminal of start-off-run switch (12).
(15)
Remove wire #45 (21) from "off'" terminal of on-off switch (22).
c. Installation.
NOTE
·
Replace wires by matching tags.
·
Make sure that wires are firmly secured.
(1)
Install wire #35 (20) onto "run" terminal of start-off-run switch (12).
(2)
Install wire #41 (16) onto piggyback terminal of wire #35 (20).
(3)
Install jumper wire #32 (18) onto "run" and "start" terminal of start-off-run switch (12).
(4)
Install wire #34 (19) onto piggyback "run" terminal of wire #32 (18).
(5)
Install wire #33 (17) onto piggyback "start" terminal of wire #32 (18) and "on" terminal of on-off switch (22).
(6)
Install wire #37 (14) onto "off" terminal of start-off-run switch 912).
(7)
Install wire #38 (13) onto "start" terminal of start-off-run switch (12).
(8)
Install wire #39 (12) onto "low" terminal of low-high switch (11) and "start" terminal of start-off-run switch (12).
(9)
Install wire #40 (10) onto "high" terminal of low-high switch (11).
(10)
Install wire #30 (8) and wire #31 (9) onto brass colored screw of circuit breaker (5). Install lockwasher (7) and hex
nut (6) onto wires #30 (8) and #31 (9) and tighten.
(11)
Install other end of wire #31 (9) onto "off' terminal of start-off-run switch (12).
(12)
Install wire #29 (15) onto silver colored screw of circuit breaker (5) and tighten, using lockwasher (7) and hex nut
(6).
(13)
Install wire #45 (21) onto "off" terminal of on-off switch (22).
(14)
Install wire #36 (4) onto circuit breaker ground (5) and tighten locknut (3).
(15)
Install control box (2). (para 4-45).
(16)
Install two electrical connectors (1). (para. 4-45).
4-144