TM 5-3825-230-14&P
5-39. HYDRAULIC PUMP ASSEMBLY REPAIR (CONT).
(9)
Remove snap ring (13) and seal (14) from front
cover (10) using snap ring pliers.
b. Cleaning/inspection.
(1)
Inspect pump parts for wear, warped, parts or corrosion.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles, face mask, and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and
don't breathe vapor. Do not use near open flame or excessive heat. The flashpoint for type I dry
cleaning solvent is 100°F (38°C) and for type II is 140°F (60°C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
flush eyes with water and get medical aid immediately.
(2)
Clean all metal parts with dry cleaning solvent P-D-680.
(3)
Replace any damaged or worn parts.
c. Assembly.
(1)
Install seal (14) and snap ring (13) in front cover (10) using snap ring pliers.
5-96