CUSHION HITCH SOLENOID REPLACEMENT
Figure 3. Coil.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  509    510    511    512    513  514  515    516    517    518    519  
img
.
TM 5-3805-296-23-6
0406
REMOVAL
000406
NOTE
Note location and quantity of tiedowns to aid in installation.
Tag and mark wiring harness connectors to aid in installation.
1. Remove tiedown strap (Figure 1, Item 2) from wiring harness (Figure 1, Item 1) and ladder clip
(Figure 1, Item 3). Discard tiedown strap.
2. Disconnect machine wiring harness connector (Figure 1, Item 5) from leveling valve harness connector
(Figure 1, Item 4).
3. Remove leveling valve harness connector (Figure 1, Item 4) from bracket (Figure 1, Item 6).
Figure 1. Wiring Connector.
0406
0406-2