FRONT HOOD REPLACEMENT
Figure 2. Tiedown Straps and 24-volt Pulse Receptacle Unit at Bracket.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  174    175    176    177    178  179  180    181    182    183    184  
img
.
TM 5-3805-296-23-6
0388
REMOVAL
000388
1. Open hood TM 5-3805-296-10.
NOTE
Tag and mark terminal and connector to aid in installation.
Note location of tiedown straps to aid installation.
Note routing of wiring harness to aid installation.
2. Remove bolt (Figure 1, Item 7), lockwasher (Figure 1, Item 6), and solargizer terminal (Figure 1, Item 5) from
bottom of NATO slave (Figure 1, Item 8). Discard lockwasher.
3. Remove tiedown strap (Figure 1, Item 3) from ladder clip (Figure 1, Item 4). Discard tiedown strap.
4. Disconnect 24-volt pulse receptacle connector (Figure 1, Item 1) from connector (Figure 1, Item 2) and remove
two fuses (Figure 1, Item 9).
Figure 1. Connections at NATO Slave.