Figure 27. Pressure Switch to Center Union Block Line.
Figure 29. Check Valve Line at Air Control Valve.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  994    995    996    997    998  999  1000    1001    1002    1003    1004  
img
.
TM 5-3805-296-23-5
0359
INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air lines and fittings.
Install air lines as tagged and marked during removal.
36. Install air line (Figure 28, Item 3) on fittings (Figure 28, Items 1 and 5).
37. Apply sealant to tube nut (Figure 28, Item 2), Install tube nut on fitting (Figure 28, Item 1).
38. Apply sealant to tube nut (Figure 28, Item 4), Install tube nut on fitting (Figure 28, Item 5).
Figure 28. Check Valve Line.
0359
0359-29