Figure 22. Wiring Harness Bolts on Floor.
Figure 24. Air Valve to Center Union Block Line.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  989    990    991    992    993  994  995    996    997    998    999  
img
.
TM 5-3805-296-23-5
0359
INSTALLATION CONTINUED
NOTE
Install tiedowns as noted during removal.
Install P-clamps as noted during removal.
16. Install new tiedown strap (Figure 23, Item 5) on air line (Figure 23, Item 7) and machine wiring harness
(Figure 23, Item 6).
17. Install P-clamp (Figure 23, Item 3), P-clamp (Figure 23, Item 1), washer (Figure 23, Item 2), and bolt
(Figure 23, Item 4) on machine.
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air lines and fittings.
Install air lines as tagged and marked during removal.
Install fittings as noted during removal.
Figure 23. Air Line P-clamps.
0359
0359-24