TM 5-3805-296-23-5
0356
DISASSEMBLY
000356
CAUTION
Do not disconnect jumper harness from air pressure sensor. Air pressure sensor damage
will occur.
NOTE
Note quantity and position of tiedown straps to aid in installation.
1. Do not disconnect connector (Figure 9, Item 1) from air pressure sensor (Figure 9, Item 2).
2. Remove clamp (Figure 9, Item 3) from relay (Figure 9, Item 4).
3. Remove tiedown straps (Figure 9, Item 7) from wiring harness (Figure 9, Item 8) and air pressure sensor
(Figure 9, Item 2). Discard tiedown straps.
4. Remove air pressure sensor (Figure 9, Item 2) and O-ring (Figure 9, Item 5) from fitting (Figure 9, Item 6).
Discard O-ring.
Figure 9. Air Pressure Sensor Relay and Sensor.
0356