REAR AIR TANK REPLACEMENT - Continued
Figure 15. Air Tank.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  619    620    621    622    623  624  625    626    627    628    629  
img
.
TM 5-3805-296-23-5
0337
ASSEMBLY CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
6. Apply sealant to fitting (Figure 14, Item 2), install fitting on air tank (Figure 14, Item 1).
7. Apply sealant to fitting (Figure 14, Item 3), install fitting on fitting (Figure 14, Item 2).
8. Apply sealant to check valve (Figure 14, Item 5), install check valve on fitting (Figure 14, Item 3).
9. Apply sealant to fitting (Figure 14, Item 4), install fitting on check valve (Figure 14, Item 5).
Figure 14. Front Air Tank Fitting.