Figure 13. Rear Air Tank Fitting.
Figure 14. Front Air Tank Fitting.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  618    619    620    621    622  623  624    625    626    627    628  
img
TM 5-3805-296-23-5
0337
ASSEMBLY
000337
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
1. Apply sealant to fitting (Figure 13, Item 2), install fitting on air tank (Figure 13, Item 1).
2. Apply sealant to fitting (Figure 13, Item 3), install fitting on fitting (Figure 13, Item 2).
3. Apply sealant to drain valve (Figure 13, Item 4), install drain valve on fitting (Figure 13, Item 3).
4. Apply sealant to fitting (Figure 13, Item 6), install fitting on air tank (Figure 13, Item 1).
5. Apply sealant to fitting (Figure 13, Item 5), install fitting on air tank (Figure 13, Item 1).
0337-14